Rotary Pulse Indicator K3HB-R CSM_K3HB-R_DS_E_16_3 Digital Rotary Pulse Meter Capable of 50 kHz Measurements * Visual confirmation of judgement results through display colors that switch between red and green. *1 * Measures High-speed Pulses at 50 kHz. Provides high-speed pulse measurements up to 50 kHz of rotary encoder or ON/OFF pulse signals and can perform rotating measurement of high-speed rotating objects. Note: No-voltage contacts of up to 30 Hz are supported. * Six Measurement Operations Including Rotation (rpm)/Circumferential Speed, Ratio, and Cumulative One Rotary Pulse Meter has 6 rotary pulse measurement functions to support a variety of pulse measurement applications. Select the best function for your application from the following: Rotation (rpm)/circumferential speed/instantaneous flowrate (value proportional to frequency), absolute ratio, error ratio, error, flow rate ratio, and passing speed (value inversely proportional to frequency). * DeviceNet models added to the series. *2 *1 Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet. You can change the display color by setting it, but you cannot switch it based on the judgement results. *2 DeviceNet models have a depth of 97 mm. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-R @ 1 K3HB-R@-@@@ 5 1. Input Sensor Code NB: NPN input/voltage pulse input PB: PNP input 5. Supply Voltage 100-240 VAC:100 to 240 VAC 24 VAC/VDC: 24 VAC/VDC Optional Boards Sensor Power Supply/Output Boards K33-@ 2 Relay/Transistor Output Boards K34-@ 3 Event Input Boards K35-@ 4 1 2 3 4 5 2. Sensor Power Supply/Output Type Code None: None CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC10%, 80 mA) (See note 1.) L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) A: Sensor power supply (12 VDC 10%, 80 mA) FLK1A: Communications (RS-232C) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) FLK3A: Communications (RS-485) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) Note: 1. CPA can be combined with relay outputs only. 2. Only one of the following can be used by each Digital Indicator: RS-232C/RS485 communications, a linear output, or DeviceNet communications. 3. Relay/Transistor Output Type Code None: None C1: Relay contact (H/L: SPDT each) C2: Relay contact (HH/H/LL/L: SPST-NO each) T1: Transistor (NPN open collector: HH/H/PASS/L/LL) T2: Transistor (PNP open collector: HH/H/PASS/L/LL) BCD *:BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL) DRT: DeviceNet (See note 2.) * A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code None: None 1: 5 inputs (M3 terminal blocks), NPN open collector 2 *: 8 inputs (10-pin MIL connector), NPN open collector 3: 5 inputs (M3 terminal blocks), PNP open collector 4 *: 8 inputs (10-pin MIL connector), PNP open collector * There is no bank selection for "None" and "DeviceNet" types of "Transistor Output Type Code". Note: The following combinations are not possible. * Communications (FLK@A) + DeviceNet (DRT) * Communications (FLK@A) + BCD output (BCD) * Linear current/voltage (L@A) + DeviceNet (DRT) 1 K3HB-R Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model K32-P1 Y92A-49N Note: Rubber packing is provided with the Controller. Specifications Ratings Supply voltage 100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC 10%, 80 mA (models with external power supply only) Event inputs (See note 2.) NPN open collector or no-voltage contact signal ON residual voltage: 2 V max. ON current at 0 : 4 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. Startup compensation timer input Hold input Reset input Bank input Output ratings Relay output (depends on the model) Transistor output Linear output 250 VAC, 30 VDC, 5 A (resistive load) Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V; no output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)) Main functions Scaling function, measurement operation selection, averaging, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Ambient operating temperature -10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature -25 to 65C (with no icing or condensation) Altitude 2,000 m max. Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 2 K3HB-R Characteristics Display range -19,999 to 99,999 Measurement accuracy (at 235C) Functions F1, F6: 0.006% rgd 1 digit (for voltage pulse/open collector sensors) Functions F2 to F5: 0.02% rgd 1 digit (for voltage pulse/open collector sensors) Measurement range Functions F1 to F6: 0.5 mHz to 50 kHz (for voltage pulse/open collector sensors) Input signals Contact input (dry contact input) (30-Hz max. with ON/OFF pulse width of 15 ms min.) No contact voltage pulse (50-KHz max. with ON/OFF pulse width of 9 s min.; ON voltage: 4.5 to 30 V; OFF voltage: -30 to 2 V; input impedance: 10 k) Open collector (50-KHz max. with ON/OFF pulse width of 9 s min.) Connectable sensors ON residual voltage: 3 V max. OFF leakage current: 1.5 mA max. Load current: Must have a switching capacity of 20 mA or higher. Must be able to properly switch load currents of 5 mA or less. Comparative output response time (transistor output) Functions F1 to F6: 100 ms max. (time until the comparative output is made when there is a forced sudden change in the input signal from 15% to 95% or 95% to 15%.) Linear output response time Functions F1 to F6: 110 ms max. (time until the final analog output value is reached when there is a forced sudden change in the input signal from 15% to 95% or 95% to 15%.) Insulation resistance 20 M min. (at 500 VDC) Dielectric strength 2,300 VAC for 1 min between external terminals and case Noise immunity 100 to 240 VAC models: 1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 s/100 ns) 24 VAC/VDC models: 1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 s/100 ns) Vibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions Weight Degree of protection Approx. 300 g (Base Unit only) Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66) Rear case IP20 Terminals IP00 + finger protection (VDE0106/100) Memory protection EEPROM (non-volatile memory) Number of rewrites: 100,000 Applicable standards UL61010-1, CSA C22.2 No.61010-1-04 EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II EN61326-1 EMC EMI: EN61326-1 Industrial electromagnetic environment Electromagnetic radiation interference CISPR 11 Group 1, Class A Terminal interference voltage CISPR 11 Group 1, Class A EMS: EN61326-1 Industrial electromagnetic environment Electrostatic Discharge Immunity EN61000-4-2: 4 kV (contact), 8 kV (in air) Radiated Electromagnetic Field Immunity EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Electrical Fast Transient/Burst Noise Immunity EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line) Surge Immunity EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted Disturbance Immunity EN61000-4-6: 3 V (0.15 to 80 MHz) Power Frequency Magnetic Immunity EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity EN61000-4-11: 0.5 cycle, 0/180, 100% (rated voltage) 3 K3HB-R Operation Functions (Operating Modes) F1 to F6 Functions F1 to F6 provide rpm/circumferential speed and other calculation displays by measuring continuous pulses (frequencies). Example Length of processing stage F1: Displays rotation (rpm) or circumferential speed for one input. F2 to F5: Displays the calculation result for two rotation (rpm) speeds. F6: Function name f1 Absolute ratio f2 Error ratio f3 Rotational difference f4 Flow rate ratio f5 Passing time f6 Function F1 Rpm/ circumferential speed/ Instantaneous flowrate The basic principle used by the Digital Indicator to calculate the rotation speed (rpm) display is to count the ON/OFF time (T) for input sensor or other device inputs using the internal system clock, and then automatically calculate the frequency. This frequency (f) is multiplied by 60 and displayed as the rotation (rpm) speed. Function No. Rpm/circumferential speed Displays the passing time calculated from the circumferential speed and the length of the processing stage for one input. Input sensor or other input pulse ON/OFF time (T) = Operation Calculation Display unit Frequency (of input pulse) Circumferential speed Instantaneous flowrate Frequency (f) = 1 T * Rotation speed (rpm) = f x 60 * Circumferential speed = Roll circumference x Rotation speed (rpm) * Passing time= Length of processing stage Circumferential speed These calculations are automatically made internally and displayed whenever any input pulse is received. Operation image (application) Measures frequency for input A and displays the Measuring roller winding speed rotation (rpm) or circumferential speed proportional to the input frequency. Display value D = fa x 60 x fa: Input frequency (Hz) Rotation speed T Measuring motor speed (for product testing) H PASS Prescale value () rpm 1/N L rps 1/60 N OK/NG judgment Hz 1/60 kHz 1/60000 mm/s 1000 d/60 N cm/s 100 d/60 N m/s d/60 N m/min d/N km/h 0.06 d/N l/min Check the output specifications of the input device and calculate the prescale value from the following equation: Display value D = a x 60 x l/h N = Pulses per rotation d = Circumferential length per rotation (m) F2 Absolute ratio Multiples input B divided by input A ( B ) by 100 and A displays the ratio as a percentage (%). Display unit: % Measuring the speed ratio between two rollers HH H PASS L LL Warning 4 K3HB-R Function F3 Error ratio Operation Operation image (application) Multiplies the error between input A and input B ( B -1) by 100 and displays the ratio as a percentage A (%). Display unit: % Measuring the line speed error ratio between two conveyors Communications output To computer (remote monitoring) F4 Rotational difference Displays the difference between input A and input B (B - A) as the rotation (rpm) speed error or circumferential speed error. Display unit: rpm, rps, rph, Hz, kHz, mm/s, m/s m/min, km/h l/min, l/h, etc. Measuring the rotation (rpm)/circumferential speed error (absolute error) between two conveyors HH H PASS L LL Warning F5 Flow rate ratio Displays the flow rate ratio of B from inputs A and B ( B ) as a ratio (%). A+B Display unit: % Monitoring liquid mixture flow rate ratio Linear output Recording meter F6 Passing time The passing time for the desired distance is displayed by measuring the frequency of input A. Displaying the passing time for a conveyor line Passing time (s) = 1/a x a: Input frequency (Hz) Set the prescale value for the desired display unit using the following table for reference. Distance Calculation Passing time Display unit Prescale value () s L/(d/N) N = Pulses per rotation d = Circumferential length per rotation (m) L = Length of process (m) Display unit: Seconds (s), minutes (min), hours/minutes/seconds (h.min.s), minutes/seconds/tenths of seconds (min.s.1/10s), etc. H PASS L Warning output 5 K3HB-R What Is Prescaling? What Is the Auto-zero Function? To make calculations using the input pulse to display rotation (rpm) or circumferential speed, the number of pulses per rotation or the length of the circumference must be multiplied by a certain coefficient. This coefficient is called the prescale value. K3HB-R (Set this function before using the Digital Indicator.) If a function f1 to f6 is set, the frequency can be force-set to zero if there is no input pulse for a set period. This period is called the autozero time. Set the auto-zero time to slightly longer than the longest input pulse interval. (The display will not easily return to zero if the auto-zero time is too long or left at the default setting.) Time Unit Settings Proximity sensor Setting Rotation speed (rpm) = f x 60 x a f: Input pulse frequency (No. of pulses per second) a: Prescale value If there are 5 pulses per rotation, then a = 1/5 (= 0.2 = 2 x 10-1) and an accurate rotation speed (rpm) can be calculated. -1 The actual setting is X = 2.0000 (mantissa) and Y = 10 (exponent). Meaning off Invalid scal Prescale value menu setting min Minute display h.mm.ss h.mm.ss display mm.ss.d mm.ss.d display (d = tenths of a second) Note: Time unit can be set only when passing time (F6) is selected. Input Type Setting NO: Voltage pulse high NC: Voltage pulse low No-contact or voltage pulse input 00 01 Contact 10 11 Note: Set to 10 or 11 when there is a large variation in the display. The largest measurement range is 30 Hz. 6 K3HB-R Common Specifications Event Input Ratings K3HB-R S-TMR, HOLD, RESET, BANK1, BANK2, BANK4 Contact ON: 1 k max., OFF: 100 k min. No-contact ON residual voltage: 2 V max. OFF leakage current: 0.1 mA max. Load current: 4 mA max. Maximum applied voltage: 30 VDC max. Output Ratings Contact Output Item Transistor Outputs Resistive loads (250 VAC, cos=1; 30 VDC, L/R=0 ms) Rated load 5 A at 250 VAC 5 A at 30 VDC Mechanical life expectancy 5,000,000 operations Electrical life expectancy 100,000 operations Inductive loads (250 VAC, closed circuit, cos=0.4; 30 VDC, L/R=7 ms) Maximum load voltage 24 VDC Maximum load current 50 mA 100 A max. Leakage current 1 A at 250 VAC 1 A at 30 VDC Linear Output Item Outputs 0 to 20 mA Allowable load impedance 500 max. Resolution Approx. 10,000 Output error 0.5% FS 4 to 20 mA 0 to 5 V Type RS-232C, RS-485 Communications method Half duplex Synchronization method Start-stop synchronization (asynchronous) Baud rate 9600/19200/38400 bps Transmission code ASCII Data length 7 bits or 8 bits Stop bit length 2 bits or 1 bit Error detection Vertical parity and FCS Parity check Odd, even 0 to 10 V 0.5% FS (0.15 V for 1 V or less and no output for 0 V) Serial Communications Output Item 1 to 5 V 5 k min. BCD Output I/O Ratings (Input Signal Logic: Negative) I/O signal name Inputs REQUEST HOLD MAX MIN RESET Item Input signal Input current for no-voltage input 10 mA Signal level ON voltage OFF voltage Outputs DATA Maximum load voltage POLARITY OVER Maximum load current DATA VALID RUN Leakage current HH H PASS L LL Rating No-voltage contact input 1.5 V max. 3 V min. 24 VDC 10 mA 100 A max. Maximum load voltage 24 VDC Maximum load current 50 mA Leakage current 100 A max. Refer to the K3HB Communications User's Manual (Cat. No. N129) for details on serial and DeviceNet communications. 7 K3HB-R DeviceNet Communications Communications protocol Supported Remote I/O communications communications Conforms to DeviceNet Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O data using the Configurator. Allocate any data, such as DeviceNet-specific parameters and variable area for Digital Indicators. Input area: 2 blocks, 60 words max. Output area: 1 block, 29 words max. (The first word in the area is always allocated for the Output Execution Enabled Flags.) Message communications Explicit message communications CompoWay/F communications commands can be executed (using explicit message communications) Connection methods Combination of multi-drop and T-branch connections (for trunk and drop lines) Baud rate DeviceNet: 500, 250, or 125 Kbps (automatic follow-up) Communications media Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line) Communications distance Baud rate Network length (max.) Drop line length (max.) Total drop line length (max.) 500 Kbps 100 m max. (100 m max.) 6 m max. 39 m max. 250 Kbps 100 m max. (250 m max.) 6 m max. 78 m max. 125 Kbps 100 m max. (500 m max.) 6 m max. 156 m max. The values in parentheses are for Thick Cable. Communications power supply 24-VDC DeviceNet power supply Allowable voltage fluctuation range 11 to 25-VDC DeviceNet power supply Current consumption 50 mA max. (24 VDC) Maximum number of nodes 64 (DeviceNet Configurator is counted as one node when connected.) Maximum number of slaves 63 Error control checks CRC errors DeviceNet power supply Supplied from DeviceNet communications connector 8 K3HB-R Connections External Connection Diagrams Terminal Arrangements Note: Refer to Internal Block Diagram on page 11 for information on isolation. A Operating Power Supply A B C D E 1 2 3 100 to 240 VAC 24 VAC/VDC 4 5 6 A1 A2 *Check the required power supply type. B Sensor Power Supply/Output Sensor power supply + PASS output C Relays, Transistors, BCD and DeviceNet B1 Relay Outputs B2 B3 N/C B4 C1 B5 Sensor 12 VDC 80 mA H + 0-5/1-5/ 0-10 V N/C N/C 0-20/ 4-20 mA Transistor Outputs HH C1 HH C1 H C2 H C2 NPN DeviceNet Connector (Included) PNP power B6 supply Sensor power supply + linear output 12 VDC 80 mA C2 Relay Outputs 1 2 3 4 5 PASS 12 VDC 80 mA L C3 COM C3 C4 L C4 L C4 C5 LL C5 LL C5 C6 B1 PASS C3 COM C6 COM C6 - B2 + B3 - B4 + B5 Sensor power - B6 supply BCD (NPN Open Collector): 1: V- (Power supply cable: Black) 2: CAN L (Communications cable: Blue) 3: Shield 4: CAN H (Communications cable: White) 5: V+ (Power supply cable: Red) Applicable Connector: HR31-5.08P-5SC (01) (HIROSE ELECTRIC CO., LTD.) * Attach the provided crimp terminals. Applicable Connector (Sold separately) K32-BCD (OMRON) (HDR-E50MAG1 with 0.3-m cable) Sensor power supply B1 The BCD COMMON is shared. The pins indicated in the above diagram as blank (white) boxes have been removed. *Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet. B2 N/C B3 B4 + 12 VDC 80 mA Contact Outputs B5 Sensor power - Transistor Outputs (NPN Open Collector) B6 supply 5V Sensor power supply + communications HH HH H H L L B (+) SD B1 A (-) RD B2 LL LL B (+) SG B3 PASS PASS A (-) N/C B4 12 VDC 80 mA 12 VDC 80 mA + power - RS-485 RS-232C B5 Sensor B6 supply Safety Standards Conformance Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. The product must be used indoors for the above applicable standards to apply. 9 K3HB-R NPN Input Model E Pulse Inputs E3, E6 12 V 510 * Rotary Pulse Meter: K3HB-R 700 700 PNP Input: K3HB-@PB E1 12 V COM E2, E5 NPN Input: K3HB-@NB PNP Input Model * NPN input section E1 E3, E6 E2 Connectable Sensors Voltage Input A E2 NPN Input B Voltage Input A PNP E3 COM E3 COM E4 E4 ON residual voltage: 3 V OFF leakage current: 1.5 mA max. * Voltage pulse input section Note: A 2-wire DC sensor can also be connected. Check the ratings and characteristics tables, however, for the connection conditions. 12 V E5 NPN Input B PNP E6 COM Note: E3 and E6, as well as B6, are internally connected. E5 510 E1, E4 E6 COM 10 k Note: E3 and E6, as well as B5, are internally connected. 700 E3, E6 ON voltage: 4.5 to 30 V OFF voltage: -30 to 2 V Connectable Sensors D Event Inputs Models with Terminal Blocks <1> <3> N/C S-TMR HOLD RESET N/C COM 510 E2, E5 COM * Use terminal pin D6 as the common terminal. * Use NPN open collector or no-voltage contacts for event input. PNP types are also available. Models with Connectors <2> <4> 1: N/C 3: HOLD 5: N/C 7: BANK4 9: BANK1 1 9 2: S-TMR 4: RESET 6: COM 8: BANK2 10 10: COM 2 12 V S-TMR: D2 HOLD: D3 RESET: D4 4.7 k * Applicable Connector (Sold separately) XG4M-1030 (OMRON) * Special Cable (Sold separately) K32-DICN (OMRON) (XG4M-1030 with 3-m cable) 3.9 k D6 COM BCD Output Cable Model Shape Pin arrangement K32-BCD Connected device end (PLC, display device, etc.) K3HB end 1 COMMON 100 101 102 300 mm 38 mm Cover: HDR-E50LPA5 (manufactured by Honda Tsushin Co., Ltd.) Connector: HDR-E50MAG1 (manufactured by Honda Tsushin Co., Ltd.) 46.5 mm D-sub connector (37-pin female) Cover: 17JE-37H-1A (manufactured by DDK) Connector: Equivalent to 17JE-13370-02 (manufactured by DDK) Stud: 17L-002A (manufactured by DDK) 103 104 1 2 4 8 1 2 4 8 1 2 4 8 1 2 4 8 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 4 104 8 OVER DATA VALID RUN COMMON REQUEST MAX REQ. MIN REQ. HOLD RESET POLARITY HH H PASS L LL COMMON Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1) (manufactured by DDK) Special Cable (for Event Inputs with 8-pin Connector) Model Appearance K32-DICN 9 10 1 2 Cable marking 3,000 mm (3 m) Wiring Pin No. 1 2 3 4 5 6 7 8 9 10 Signal name N/C S-TMR HOLD RESET N/C COM BANK4 BANK2 BANK1 COM 10 K3HB-R Derating Curve for Sensor Power Supply (Reference Values) Maximum current (mA) For 12V 140 1 120 100 80 60 40 20 0 -20 -10 0 10 20 30 40 50 60 Ambient temperature (C) Note: 1. The above values were obtained under test conditions with the standard mounting. The derating curve will vary with the mounting conditions, so be sure to adjust accordingly. 2. Internal components may be deteriorated or damaged. Do not use the Digital Indicator outside of the derating range (i.e., do not use it in the area labeled A, above). Internal Block Diagram Waveform shaping circuit Keys EEPROM Indications * Input circuit * Output circuit * Transistor output circuit Drive circuit Drive circuit Event input Digital input circuit Waveform shaping circuit Linear output Linear output circuit Drive circuit Sensor power supply Filter Pulse input Pulse input circuit BCD BCD I/O Microcomputer VO Drive circuit Transistor output Relay output X Drive circuit DeviceNet circuit DeviceNet Drive circuit Communications driver Communications VCOM VDD Power supply circuit (isolated) VO DC-DC Converter (isolated) Power supply 11 K3HB-R BCD Output Timing Chart A REQUEST signal from a Programmable Controller or other external device is required to read BCD data. Single Sampling Data Output Continuous Data Output 20-ms pulse min. (50 ms max.) REQ. MAX.MIN. REQ. MAX.MIN. DATA DATA All data "High" All data "High" Data 1 Data 2 All data "High" Data DATA VALID DATA VALID Approx. 30 ms 40 ms 40 ms Approx. 30 ms 16 ms The data is set in approximately 30 ms from the rising edge of the REQUEST signal and the DATA VALID signal is output. When reading the data from a Programmable Controller, start reading the data when the DATA VALID signal turns ON. The DATA VALID signal will turn OFF 40 ms later, and the data will turn OFF 16 ms after that. 40 ms 24 ms 64 ms 24 ms 64 ms Measurement data is output every 64 ms while the REQUEST signal remains ON. Note: If HOLD is executed when switching between data 1 and data 2, either data 1 or data 2 is output depending on the timing of the hold signal. The data will not go LOW. * The K3HB BCD output model has an open collector output, so wired OR connection is possible REQ. (1) K3HB (1) Programmable Controller REQ. (2) K3HB (2) REQ. (3) DATA (including POL and OVER) and DATA VALID can be used in a wired OR. RUN, HH, H, PASS, L, and LL are always output, with or without a REQUEST signal. Do not used a wired OR connect for these signals. K3HB (3) (1) DATA (2) (3) DATA VALID (See note.) (See note.) (See note.) Note: Leave 20 ms min. between DATA VALID turning OFF and the REQUEST signal. Programmable Controller Connection Example Digital Indicator Connector pin No. (See note.) 1.COMMON COM 2.1 3.2 Connector pin No. (See note.) 1.COMMON IN 2.1 IN 3.2 IN 4.4 10 5.8 Display Unit Connection Example Digital Indicator Internal circuit 4.4 SYSMAC Programmable Controller DC Input Unit IN 5.8 23.DATA VALID 23.DATA VALID 24.RUN 10 24.RUN IN To 101 IN To 102 240 240 240 25.COMMON Short26.REQUEST circuit 240 Internal circuit +5 V Transistor Output Unit OUT 30.RESET OUT 31.POLARITY (+/- polarity) COM (0 V) 24 VDC +5 V 240 240 30.RESET 240 240 31.POLARITY (+/- polarity) V O D C B A DP LE V O D C B A DP LE V O D C B A DP LE V O 26.REQUEST Internal circuit 25.COMMON 8 8 8 SEC M7E-01D@N2, 01H@N2 +24 V 0V * DC power supply Note: The BCD output connector pin number is the D-sub connector pin number when the BCD Output Cable (sold separately) is connected. This number differs from the pin number for the Digital Indicator narrow pitch connector (manufactured by Honda Tsushin Kogyo Co., Ltd.). *M7E series were discontinued at the end of March, 2020. Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator: K3HB-R/P/C Digital Indicator User's Manual (Cat. No. N136) The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp 12 K3HB-R Component Names and Functions Max./Min. status indicator PV display Turns ON when the maximum value or minimum value is displayed in the RUN level. Displays PVs, maximum values, minimum values, parameter names, and error names. Level/bank display Position meter In RUN level, displays the bank if the bank function is ON. (Turns OFF if the bank function is OFF.) In other levels, displays the current level. Displays the position of the PV with respect to a desired scale. Comparative output status indicators SV display Display the status of comparative outputs. HH H P L Displays SV and monitor values. Max Min B L CMW Hold LL T HH H LL L Status indicators SV display status indicators MAX/MIN Function Display CMW Lit when communications writing is ON (enabled) and not lit when OFF (prohibited). Hold Turns ON/OFF when HOLD input turns ON/OFF. MAX/MIN Key Used to switch the display between the PV, maximum value, and minimum value and to reset the maximum and minimum values. LEVEL Key Used to switch level. LEVEL MODE SHIFT UP Indicator T MODE Key Used to switch the parameters displayed. HH H LL L T HH, H, L, LL SHIFT Key Used to change parameter settings. When changing a set value, this key is used to move along the digits. Function Turns ON when parameters for which teaching can be performed are displayed. In RUN level, turn ON when the comparative set value HH, H, L, or LL is displayed. UP Key When changing a set value, this key is used to change the actual value. When a measurement value is displayed, this key is used to execute or clear the forced-zero function or to execute teaching. 13 K3HB-R Dimensions 101.2 91 Terminal cover (included) Panel Cutout Dimensions Character Size for Main Display (mm) PV display SV display 120 min. 4.9 14.2 100 3.5 (112) 7.6 75 min. 92+0.8 0 45+0.6 0 12 1.3 95 * 2 96 Mounting Recommended Panel Thickness 1 to 8 mm. Mount the product horizontally. 44.8 48 *DeviceNet models: 97 mm Terminal: M3, Terminal Cover: Accessory Wiring Precautions Mounting Method * For terminal blocks, use the crimp terminals suitable for M3 screws. * Tighten the terminal screws to the recommended tightening torque of approx. 0.5 N*m. * To prevent inductive noise, separate the wiring for signal lines from that for power lines. 1. Insert the K3HB into the mounting cutout in the panel. 2. Insert watertight packing around the Unit to make the mounting watertight. Watertight packing Wiring * Use the crimp terminals suitable for M3 screws shown below. 5.8 mm max. 5.8 mm max. 3. Insert the fixture into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in place. Unit Stickers (included) Fixture * No unit stickers are attached to the Digital Indicator. * Select the appropriate units from the unit sticker sheets provided. LCD Field of Vision The K3HB is designed to have the best visibility at the angles shown in the following diagram. Note: For measurements for commercial purposes, be sure to use the unit required by any applicable laws or regulations. 10 30 Watertight Cover Rubber Packing Y92A-49N K32-P1 If the rubber packing is lost or damaged, it can be ordered using the following model number: K32-P1. (Depending on the operating environment, deterioration, contraction, or hardening of the rubber packing may occur and so, in order to ensure the level of waterproofing specified in NEMA4, periodic replacement is recommended.) Note: Rubber packing is provided with the Controller. 14 K3HB-R Main Functions Main Functions and Features Measurement Function Input Compensation func The K3HB-R has the following six functions for receiving and displaying input pulses. F1: Rotation (rpm)/circumferential speed Auto-zero Times at.za, at.zb The frequency is forced to zero if there is no pulse input for a set period. F2: Absolute ratio Key Operations F3: Error ratio Teaching F4: Rotational difference The present measurement value can be used as a scaling value. F5: Flow rate ratio F6: Passing time Key Protection The K3HB-P has the following six functions for receiving and displaying input pulses. Key protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions. F1: Passing speed F2: Cycle F3: Time difference F4: Time band F5: Measuring length F6: Interval The K3HB-C has the following three functions for receiving and displaying input pulses. F1: Individual inputs F2: Phase differential inputs F3: Pulse counting input Filters Average Processing avg-t, avg-n Average processing of input signals with extreme changes or noise smooths out the display and makes control stable. Input Types in-ta, in-tb Specify the types of sensor connected to input A and input B. 15 K3HB-R Outputs Display Comparative Output Pattern out-p Standard, zone, and level comparative output patterns can be selected for comparative outputs. hys Hysteresis Prevents comparative outputs from chattering when the measurement value fluctuates slightly near the set value. Output Refresh Stop o-stp Holds the output status when a comparative result output other than PASS turns ON. PASS Output Change pass Comparative results other than PASS can be output from the PASS output terminal. Output OFF Delay off-d Delays turning OFF comparatives for a set period. This can be used to provide sufficient time to read the comparative output ON status when the comparative result changes at short intervals. Display Value Selection The display value can be set to the present value, the maximum value, or the minimum value. Display Color Selection Turns ON the comparative output for a specific time. out-n Output Logic Reverses the output logic of comparative results. Startup Compensation Timer s-tmr Measurements can be stopped for a set time using an external input. color The present value display color can be set to green or red. The color of the present value can also be switched according to the comparative output. Display Refresh Period d.ref When the input changes rapidly, the display refresh period can be lengthened to control flickering and make the display easier to read. Position Meter pos-t, pos-h, pos-l The present measurement value can be displayed as a position in relation to the scaling width on a 20-gradation position meter. Prescale ps.ax, ps.ay, ps.bx, ps.by The input signal can be converted and displayed as any value. Comparative Set Value Display shot Shot Output disp sv.dsp Select whether or not to display the comparative value during operation. Display auto-return ret Automatically returns the display to RUN level when there are no key operations (e.g., max./min. switching, bank settings using keys). Other Max./Min. Hold Holds the maximum and minimum measurement values. test Output Test Output operation can be checked without using actual input signals by using the keys to set a test measurement value. lset.c, lset.v, lset.h, lset.l Linear Outputs A current or voltage proportional to the change in the measurement value can be output. Standby Sequence stdby Bank Selection bnk-c Switch between 8 comparative value banks using the keys on the front panel or external inputs. A set of set comparative values can be selected as a group. Bank Copy copy Any bank settings can be copied to all banks. The comparison outputs can be kept OFF until the measurement value enters the PASS range. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 16 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2020.3 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2020 All Right Reserved.